Fluke 1587 FC
Article Number: 4691215
High -performance 2-in-1 Insulation digital multimeter combining an insulation tester with a full featured true rms digital multimeter in a single handheld unit
Comes complete with a calibration Certificate Traceable to National Standards when purchased new.
Contact us for further information regarding the Fluke 1587 FC Insulation Multimeter Tester
Providing versatility for both troubleshooting and preventive maintenance.
The 1587 FC adds four powerful diagnostic functions through the Fluke Connect® Measurements app:
Fluke Connect Compatible
Download the free Fluke Connect ® app from Apple Store or Google Play to enable graphs within the PI/DAR function, memory storage, and temperature compensation.
Features:
What’s Included in the box:
Electrical Specifications: | ||||
AC voltage measurement | ||||
Range | Resolution | Accuracy 50 Hz to 60 Hz ± (% of rdg + counts) | Accuracy 60 Hz to 5000 Hz ± (% of rdg + counts) | |
600 mV | 0.1 mV | ± (1% + 3) | ± (2% + 3) | |
6.000 V | 0.001 V | ± (1% + 3) | ± (2% + 3) | |
60.00 V | 0.01 V | ± (1% + 3) | ± (2% + 3) | |
600.0 V | 0.1 V | ± (1% + 3) | ± (2% + 3) | |
1000 V | 1 V | ± (2% + 3) | ± (2% + 3) | |
Low Pass Filter Voltage measurement | ||||
Range | Resolution | Accuracy 50 Hz to 60 Hz ± (% of rdg + counts) | Accuracy 60 Hz to 400 Hz ± (% of rdg + counts) | |
600 mV | 0.1 mV | ± (1% + 3) | + (2% + 3) - (6% - 3) | |
6.000 V | 0.001 V | ± (1% + 3) | + (2% + 3) - (6% - 3) | |
60.00 V | 0.01 V | ± (1% + 3) | + (2% + 3) - (6% - 3) | |
600.0 V | 0.1 V | ± (1% + 3) | + (2% + 3) - (6% - 3) | |
1000 V | 1 V | ± (2% + 3) | + (2% + 3) - (6% - 3) | |
DC voltage measurement | ||||
Range | Resolution | Accuracy ± (% of rdg + counts) | ||
6.000 V | 0.001 V | ± (0.9% + 2) | ||
60.00 V | 0.01 V | ± (0.9% + 2) | ||
600.0 V | 0.1 V | ± (0.9% + 2) | ||
1000 V | 1 V | ± (0.9% + 2) | ||
DC millivolts measurement | ||||
Range | Resolution | Accuracy ± (% of rdg + counts) | ||
600.0 mV dc | 0.1 mV | ± (0.1% + 1) | ||
DC and AC current measurement | ||||
Range | Resolution | Accuracy ± (% of rdg + counts) | ||
AC 45 Hz to 1000 Hz | 400 mA | 0.1 mA | ± (1.5% +2) | |
60 mA | 0.01 mA | ± (1.5% +2) | ||
DC | 400 mA | 0.1 mA | ± (0.2% +2) | |
60 mA | 0.01 mA | ± (0.2% +2) | ||
Ohms measurement | ||||
Range | Resolution | Accuracy ± (% of rdg + counts) | ||
600.0 Ω | 0.1 Ω | ± (0.9% +2) | ||
6.000 kΩ | 0.001 kΩ | |||
60.00 kΩ | 0.01 kΩ | |||
600.0 kΩ | 0.1 kΩ | |||
6.000 MΩ | 0.001 MΩ | |||
50.00 MΩ | 0.01 MΩ | ± (1.5% + 3) | ||
Diode test | ||||
Diode test indication | Display voltage drop: 0.6 V at 1.0 mA nominal test current | |||
Accuracy | ± (2% + 3) | |||
Continuity test | ||||
Continuity indication | Continuous audible tone for test resistance below 25 Ω and off above 100 Ω. Maximum reading : 1000 Ω | |||
Open circuit voltage | < 8.0 V | |||
Short circuit current | 1.0 mA typical | |||
Overload protection | 1000 V rms | |||
Response time | > 1 m sec | |||
Frequency measurement | ||||
Range | Resolution | Accuracy ± (% of rdg + counts) | ||
99.99 Hz | 0.01 Hz | ± (1.0% + 1) | ||
999.9 Hz | 0.1 Hz | ± (1.0% + 1) | ||
9.999 kHz | 0.001 kHz | ± (1.0% + 1) | ||
99.99 kHz | 0.01 kHz | ± (1.0% + 1) | ||
Frequency counter sensitivity | ||||
Input range | V ac Sensitivity (RMS Sine Wave) | DC Trigger levels at 20 kHz | ||
5 Hz to 20 kHz | 20 kHz to 100 kHz | |||
600 mV ac | 100 mV | 150 mV | NA | |
6.0 V | 1.0 V | 1.5 V | -400.0 mV and 2.5 v | |
60.0 V | 10.0 V | 36.0 V | 1.2 V and 4 V | |
600.0 V | 100.0 V | 12.0 V and 40.0 V | ||
1000.0 V | 300.0 V | 12.0 V and 40.0 V | ||
Capacitance measurement | ||||
Range | Resolution | Accuracy ± (% of rdg + counts) | ||
1000 nF | 1 nF | ± (1.2% + 2) | ||
10.00 uF | 0.01 uF | ± (1.2% + 2) | ||
100.0 uF | 0.1 uf | ± (1.2% + 90 counts) | ||
9999 uF | 1 uF | ± (1.2% + 90 counts) | ||
Temperature measurement | ||||
Range | Resolution | Accuracy ± (% of rdg + counts) | ||
-40°C to 537°C | 0.1°C | ± (1.0% + 10 counts) | ||
-40°F to 998°F | 0.1°F | ± (1.0% + 18 counts) | ||
Insulation Specifications: | ||||
Measurement range | 0.01 MΩ to 2 GΩ | |||
Test voltage | 50, 100, 250, 500, 1000 V | |||
Test voltage accuracy | +20%, -0% | |||
Short-Curcuit test current | 1 mA nominal | |||
Auto Discharge | Discharge time <0.5 second for C = 1 uF or less | |||
Live circuit detection | inhibit test if terminal voltage > 30 V prior to initialization | |||
Maximum capacitive load | Operable with up to 1 uF load | |||
Ouput voltage | Display Range | Resolution | Test current | Resistance accuracy ± (% of Rdg + Counts) |
50 V (0% to +20%) | 0.01 to 6.00 MΩ | 0.01 MΩ | 1mA @ 50 kΩ | ± (3% +5 counts) |
6.0 to 50 MΩ | 0.1 MΩ | |||
100 V (0% to +20%) | 0.01 to 6.00 MΩ | 0.01 MΩ | 1mA @ 100 kΩ | ± (3% +5 counts) |
6.0 to 60.0 MΩ | 0.1 MΩ | |||
60 to 100.0 MΩ | 1 MΩ | |||
250 V (0% to +20%) | 0.1 to 60.0 MΩ | 0.1 MΩ | 1mA @ 250 kΩ | ± (1.5% +5 counts) |
60 to 250.0 MΩ | 1 MΩ | |||
500 V (0% to +20%) | 0.1 to 60.0 MΩ | 0.1 MΩ | 1mA @ 500 kΩ | ± (1.5% +5 counts) |
60 to 500.0 MΩ | 1 MΩ | |||
1000 V (0% to +20%) | 0.1 to 60.0 MΩ | 0.1 MΩ | 1mA @ 1 MΩ | ± (1.5% +5 counts) |
60 to 600.0 MΩ | 1 MΩ | |||
0.6 to 2.0 GΩ | 100 MΩ | ± (10% + 3 counts) | ||
General Specifications: | ||||
Maximum voltage applied to any terminal and common | 1000V | |||
Storage temperature | -40°C to 60° (-40°F to 140°F) | |||
Operating temperature | -20°C to 55°C (-4°F to 131°F) | |||
Temperature coefficient | 0.05 x (specified accuracy) per °C for temperature <18°C or >28°C (<64°F or >85°F) | |||
Relative humidity | Noncondensing | |||
0% to 95% @ 10°C to 30°C | (50°F to 86°F) | |||
0% to 75% @ 30°C to 40°C | (86°F to 104°F) | |||
0% to 40% @ 40°C to 55°C | (104°F to 131°F) | |||
Vibration | Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument | |||
Radio frequency communication | 2.4 GHz ISM Band | |||
Radio frequency certification | FCC: T68-FBLE, IC: 6627A-FBLE | |||
Electromagnetic compatibility | ||||
International IEC 61326-1:Portable electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A | Group 1:Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment | |||
Class A:Equipment is suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatiblity in other environments due to conducted and radiated distrubances. | ||||
Emmission that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected. | ||||