Article Number: 3947858
The Fluke 87V industrial digital multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment.
Fluke 87V comes complete with a calibration certificate traceable to National Standards when purchased from us at no extra charge.
Contact us for further information regarding Fluke 87V
The Fluke 87V TRMS Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment even in loud, high energy, and high-altitude locations.
This digital multimeter takes the guesswork out of drive system troubleshooting. This electrical multimeter includes a unique function for accurately measuring noisy at the VFD and at the motor terminals. Special shielding blocks high frequency, high-energy noise generated by large drive systems.
The 87V has improved measurement functions, troubleshooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution, and electro-mechanical equipment.
Other useful features
Applications
For Application engineer / Plant engineer / Industrial electricians (Working with VSD’s) / Electrical engineer. In plant automation, Power distribution, Electro-mechanical equipment, Industrial electronics, setting up / repairing, adjustable speed motor drives.
Specifications |
||
Voltage DC |
Maximum voltage |
1000 V |
Accuracy |
±(0.05% + 1) |
|
Maximum resolution |
10 µV |
|
Voltage AC |
Maximum voltage |
1000 V |
Accuracy |
±(0.7% + 2) True RMS |
|
AC bandwidth |
20 kHz with low pass filter; 3 db @ 1 kHz |
|
Maximum resolution |
0.1 mV |
|
Current DC |
Maximum amps |
10 A (20 A for 30 seconds maximum) |
Amps accuracy |
±(0.2% + 2) |
|
Maximum resolution |
0.01 µA |
|
Current AC |
Maximum amps |
10 A (20 A for 30 seconds maximum) |
Amps accuracy |
±(1.0% + 2) True RMS |
|
Maximum resolution |
0.1 µA |
|
Resistance |
Maximum resistance |
50 MΩ |
Accuracy |
±(0.2% + 1) |
|
Maximum resolution |
0.1 Ω |
|
Capacitance |
Maximum capacitance |
9,999 µF |
accuracy |
±(1% + 2) |
|
Maximum resolution |
0.01 nF |
|
Frequency |
Maximum frequency |
200 kHz |
Accuracy |
±(0.005% + 1) |
|
Maximum resolution |
0.01 Hz |
|
Duty cycle |
Maximum duty cycle |
99.9% |
Accuracy |
±(0.2% per khz + 0.1%) |
|
Maximum resolution |
0.1% |
|
Temperature measurement |
–200.0 °C – 1090 °C |
|
80 BK temperature probe |
–40.0 °C – 260 °C |
|
Conductance |
Maximum conductance |
60.00 nS |
Accuracy |
±(1.0% + 10) |
|
Maximum resolution |
0.01 nS |
|
Diode |
Range |
3 V |
Resolution |
1 mV |
|
Accuracy |
±(2% + 1) |
|
Duty cycle range |
Accuracy |
Within ±(0.2% per kHz + 0.1%) |
Environmental Specifications |
||
Operating temperature |
–20 °C to + 55 °C |
|
Storage temperature |
–40 °C to + 60 °C |
|
Humidity (without condensation) |
0% – 90% (0 °C – 35 °C) |
|
Operating Altitude |
2000 m |
|
Safety Specifications |
||
Overvoltage category |
EN 61010–1 to 1000 V CAT III, 600V CAT IV |
|
Agency approvals |
UL, CSA, TÜV, VDE listed |
|
Mechanical and General Specifications |
||
Size |
201 x 98 x 52 mm (with holster) |
|
Weight |
355 g |
|
Display |
Digital |
6000 counts updates 4/sec. |
Analog |
32 segments, updates 40/sec |
|
Frequency |
19,999 counts, updates 3/sec at > 10 Hz |
|
Warranty |
Lifetime |
|
Battery Life |
Alkaline |
~400 hours typical, without backlight |
Shock |
1 Meter drop per IEC 61010–1:2001 |
|
Vibration |
Per MIL–PRF–28800 for a Class 2 instrument |