Comes complete with a calibration Certificate Traceable to National Standards when purchased new.
The HPAT500/2 HandyPAT is an easy to use hand held lightweight portable PAT tester with simple one-button test selection. The tester comes with rechargeable batteries and mains charger for low cost of ownership and can be used whilst recharging ensuring no downtime.
A single button press activates either a full Class I, Class II or lead test without any further interaction, unless a failure is encountered. The display clearly shows PASS / FAIL and all test results on screen. Simple connection diagrams are permanently shown on the case body.
Specifications
Earth continuity |
Test current: 200mA DC Range: 0-19.99Ω Resolution: 0.01Ω Accuracy: ± (5% rdg + 2 dgt) Fixed pass limits: ≤ 0.10Ω/≤ 0.20Ω |
Insulation |
Test Voltage: 250V/500V DC selectable Test current: 1.5mA Ranges: 2.00MΩ, 20.0MΩ, 200MΩ Resolution: 0.01MΩ Accuracy: <100MΩ ± (5% rdg + 2 dgt), >100MΩ ± (10% rdg + 2 dgt) |
Default pass level |
Lead: ≥ 1.0 MΩ Class I: ≥ 1.0 MΩ Class II: ≥ 2.0 MΩ |
Fuse test |
Voltage: 4V DC (open circuit) Current: 200mA DC (short circuit) Pass level: >2mA |
Overload protection |
300V AC/DC |
Complies with |
BS EN 61010 |
Temperature range |
-10 to 40°C |
Supply |
6 x 1.2V AA NiMH rechargeable batteries 1800mAh |
Dimensions |
90 x 210 x 54mm |
Weight |
700g (inc batteries & leads) |
Includes |
TC57 carry case, PSUHPAT230 mains charger, rechargeable batteries, EX332 IEC lead, TL67 earth bond probe and manual |
Included
A comprehensive range of optional adaptor leads are available enabling 110V appliance testing and testing of equipment terminated with 3 phase plugs.
HPAT500/2 PAT tester comes complete with a Calibration Certificate Traceable to National Standards when purchased new.
Contact us for further information regarding HPAT500/2 PAT tester.