Martindale HPAT400 HandyPAT Tester

Martindale HPAT400 HandyPAT Tester

Fluke i3000s AC Current Clamp

Fluke i3000s AC Current Clamp

Martindale VR2240 Installation Tester

£118.80 £99.00
Availability: In stock
SKU
Martindale VR2240 Installation Tester

Martindale VR2240 16th Edition Installation Tester

This is an all-in-one tester which incorporates continuity, insulation resistance, RCD, earth loop impedance, phase loop impedances, earth resistance and phase rotation tests.

The VR2240 comes complete with test leads, protective carry case and user guide.

Comes complete with free of charge traceable calibration and certification.

Contact us if you require any further assistance with any Martindale product.

 

Martindale VR2240 16th Edition Installation Tester

This is an all-in-one tester which incorporates continuity, insulation resistance, RCD, earth loop impedance, phase loop impedances, earth resistance and phase rotation tests.

The VR2240 comes complete with test leads, protective carry case and user guide.

Functions

  • Low ohm – Continuity test to earth, protective and equalizing potential conductors with test currents higher than 200mA and open circuit voltage ranging from 4 to 24V
  • Riso – Measurement of insulation resistance with DC test voltage at 50V, 100V, 250V, 500V or 1000V.
  • RCD – Measurement on general and/or selective AC type of the following parameters:
    • Tripping rime
    • Tripping current
    • Contact voltage
    • Overall earth resistance (In this mode VR2240 can measure the overall earth resistance without causing RCD’s to trip)
  • RCD – Measurement on general and/or selective RCD’s A type of the following parameters:
    • Tripping time
    • Tripping current
    • Contact voltage
    • Overall earth resistance In this mode VR2240 can measure the overall earth resistance without causing RCD’s to trip)
  • Loop – Measurement of the line and fault loop impedance with calculation of prospective short circuit current
  • R@15mA – Measurement of fault loop impedance between earth and phase conductors with current of 15mA and calculation of prospective short circuit current.
  • Phase – Indication of phase rotation sequence.

Technical Specification

Continuity (low ohms)

Test mode

Measuring range (ohm)

Resolution (ohm)

Accuracy

Auto R+, R-

0.01 – 19.99

0.01

± (2% rdg + 2 dgt)

20.0 – 99.9

0.1

R+ timer, R- timer

0.01 – 9.99

0.01

Test current

>200 mA DC up to 16 ohm (include the resistance of the calibration)

40 mA DC from 16 ohm to 99.9 ohm

Test current resolution

1 mA

Open circuit test voltage

9 V

Insulation resistance (Riso)

Test voltage

Measuring range (Mohm)

Resolution (Mohm)

Accuracy

50

0.05 – 19.99

0.01

± (2% rdg + 2 dgt)

20.0 – 49.9

0.1

50.0 – 99.9

0.1

± (5% rdg + 2 dgt)

100

0.10 – 19.99

0.01

± (2% rdg + 2 dgt)

20.0 – 99.9

0.1

100.0 -199.9

0.1

± (5% rdg + 2 dgt)

250

0.23 -19.99

0.01

± (2% rdg + 2 dgt)

20.0 – 199.9

0.1

200 - 249

1

250 - 499

1

± (5% rdg + 2 dgt)

500

0.25 – 19.99

0.01

± (2% rdg + 2 dgt)

20.0 – 199.9

0.1

200 – 499

1

500 - 999

1

± (5% rdg + 2 dgt)

1000

0.90 – 19.99

0.01

± (2% rdg + 2 dgt)

20.0 – 199.9

0.1

200 – 999

1

1000 - 1999

1

± (5% rdg + 2 dgt)

Open circuit voltage

Rated voltage test -0% +10%

Short Circuit current

<3.0mA – 500V

<2.0mA -50V, 100V, 250V, 1000V

Test current on load

>1mA @ Vtest across Rload = (1000 x Vtest)ohm

RCD Tripping Tests

Type of RCD

AC, A

Range of phase to earth voltage

(100 – 265) V

Rated tripping currents

10mA, 30mA, 100mA, 300mA, 500mA

Test frequency

50 Hz ± 0.5 Hz

RCD Tripping time

Measuring range (ms)

Resolution (ms)

Accuracy

x1/2, x 1, - 0 to 999

1

± (2% rdg + 2 dgt)

X2 – 0 to 200 general

X2 - 0 to 250 selective

X5 – 0 to 50 general

X5 – 0 to 160 selective

RCD Contact Voltage

Measuring range (V)

Resolution (V)

Accuracy

0 - 2UtLim

0.1

-0%, +(10% rdg+2dgt)

Earth resistance RA without RCD tripping

Measuring range (ohm)

Resolution (ohm)

Accuracy

1 - 1999

1

± (5% rdg + 2 dgt)

Tripping current ramp test RCD type A and AC with I <= 10mA

Type

Measuring range mA

Resolution

Accuracy

AC

0.5 – 1.4

0.1

-0%, +10%

A

0.5 - 2.4

RCD with I > 10mA

AC

0.5 – 1.4

0.1

-0%, +10%

A

0.5 - 2.4

AC Voltage

Electrical Systems

Measuring range V

Resolution V

Accuracy

Single-phase system

0 – 265

1

± (2% rdg + 2 dgt)

2 or 3 – phase system

0 - 460

± (5% rdg + 2 dgt)

Frequency

Measuring range Hz

Resolution Hz

Accuracy

15.3 – 99.9

0.1

± (0.1% rdg + 1 dgt)

Phase-Neutral Loop impedance (loop Zs/lk phase to phase or phase to neutral)

Test Mode

Measuring Range (ohm)

Resolution

Accuracy

P-P and P-N

0.03 - 19.99

0.01

± (5% rdg + 2 dgt)

20.0 -199.9

0.1

Phase-Earth Loop impedance (Loop Zs/lk)

Measuring range (ohm)

Resolution (ohm)

Accuracy

0.03 – 19.99

0.01

± (5% rdg + 2 dgt)

20.0 – 199.9

0.1

200 - 1999

1

Non-Trip Earth Resistance (R@15mA)

Range (Ohm)

Resolution (ohm)

Accuracy

1 - 1999

1

± (5% rdg + 2 dgt)

 

Comes complete with free of charge traceable calibration and certification.