Comark N9002 Differential Thermometer
Comark N9002 Differential thermometer with eight thermocouple compatibility for maximum versatility in industrial, heating, ventilating, air conditioning and refrigeration.
Comark N9002 Differential thermometer with eight thermocouple compatibility for maximum versatility in industrial, heating, ventilating, air conditioning and refrigeration.
Compatible with thermocouple types K, N, T, J, R, S, E and B. (sold separately)
With an overall temperature measurement capability ranging from -200°C to +1820°C, it allows users to select the best thermocouple for the application. Twin sub-miniature probe connectors also allow differential temperatures to be measured, with readings displayed in °C, °F or K. It can also be used as a conventional thermometer when a single probe is connected. Comark’s IP67 rated premium case adds to the instrument’s versatility.
BioCote®
Selected Comark thermometers, probes and data loggers have BioCote’s silver technology incorporated into instrument cases and probe handles at the time of manufacture. The antimicrobial finish inhibits the growth of bacteria, reducing the risk of cross-contamination and infection in the environment. BioCote® has been officially recognised for its benefits within the food industry with HACCP International Certification. HACCP International Certification supports organisations that demonstrate food safety excellence in non-food products that are designed for, or are commonly used in, the food industry. BioCote® is the only antimicrobial solution to be awarded HACCP International Certification.
Features
- Single and Dual (Differential) Inputs
- Maximum and minimum temperature memory
- Displays temperature in °C, °F and K
- Hold function to freeze displayed reading
- Calibration – BS EN 60584 thermocouples (ITS90)
- Selectable auto switch off
- Sub-miniature connector
- Dust and waterproof to IP67
Benefits
- Free certificate of conformity
- Two-year warranty
- BioCote® antimicrobial protection
Specification
Sensors |
Thermocouples types K, N, T, J, R, S, E, B |
Connector |
Sub-miniature |
Measurement Range Thermocouple Type K Thermocouple Type N Thermocouple Type T Thermocouple Type J Thermocouple Type R and S Thermocouple Type E Thermocouple Type B |
-200°C to +1820°C (depending on sensor) -200°C to +1372°C, -328°F to 2502°F -200°C to +1300°C, -328°F to 2372°F -200°C to +400°C, -328°F to 752°F -200°C to +1200°C, -328°F to 2192°F -50°C to +1767°C, -58°F to 3212°F -200°C to +1000°C, -328°F to 1832°F +100°C to +1820°C, +212°F to 3308°F |
Display Resolution |
0.1° below +1000°, 1° above (auto ranging) |
Calibration |
BS EN 60584 thermocouples (ITS90) |
Scales |
°C, °F, K |
Accuracy at +23°C/73°F, full range, Type K only |
<±0.1% of reading ±0.2°C/0.4°F |
Operating Range |
-25°C to +50°C -13°F to +122°F |
Environmental Protection |
IP67 BS EN 60529 IEC 529 |
Battery Type |
2 x Type IEC LR6 Size AA |
Battery Life |
200 hours |
If you require any help with your selection, or any further information on the Comark range, please contact us