The Fluke 1662 gives you Fluke reliability and all the basic testing power you need for day-in, day-out installation testing. It tests to all local regulations and is easy and intuitive to use. Additional helpful features like the On / Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.
AC voltage measurement |
||
Range |
500 V |
|
Resolution |
0.1 V |
|
Accuracy 45 Hz – 66 Hz |
0.8% + 3 |
|
Input impedance |
360 kΩ |
|
Overload protection |
660 V rms |
|
Continuity testing (RLO) |
||
Range (autoranging) |
20 Ω / 200 Ω / 2000 Ω |
|
Resolution |
0.01 Ω / 0.1 Ω / 1 Ω |
|
Open Circuit Voltage |
>4 V |
|
Insulation resistance measurement (RISO) |
||
Accuracy of tTest voltage (at rated test current) |
+10%, -0% |
|
Test voltage |
100 V |
|
Insulation resistance range |
20 MΩ / 50 MΩ |
|
Resolution |
0.01 MΩ / 0.1 MΩ |
|
Test current |
1 mA @ 50 kΩ |
|
Loop and line impedance (ZI) |
||
Range |
10 Ω / 0.001 Ω / High current mΩ mode |
|
Resolution |
0.01 Ω / 0.1 Ω / 1 Ω |
|
Prospective earth fault current, PSC test |
||
Range |
1000 A / 10 kA (50 kA) |
|
Resolution |
1 A / 0.1 kA |
|
Computation |
Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively. |
|
RCD testing, RCD types tested |
||
RCD Type |
A4, AC¹, G², S³ |
|
Notes |
¹Responds to AC |
|
Tripping speed test (ΔT) |
||
Current settings¹ |
10-30-100-300-500-1000 mA – VAR |
|
Multiplier |
x ½, x 1 |
|
Measurement range |
RCD Type G |
310 ms |
RCD Type S |
510 ms |
|
Notes |
¹1000 mA type AC only |
|
RCD/FI-Tripping Current Measurement/Ramp Test (IΔN) |
||
Current range |
30% to 110% of RCD rated current¹ |
|
Step size |
10% of IΔN² |
|
Dwell time |
Type G |
300 ms/step |
Type S |
500 ms/step |
|
Measurement accuracy |
±5% |
|
Specified trip current ranges (EN 61008-1) |
50% to 100% for Type AC |
|
Notes |
¹30% to 150% for Type A IΔN > 10 mA |
|
Phase Sequence Indication |
||
Icon |
Phase Sequence indicator is active. |
|
General Specifications |
||
Size (L x W x H) |
10 x 25 x 12.5 cm |
|
Weight (incl. batteries) |
1.3 kg |
|
Battery size, quantity |
Type AA, x 6 |
|
Sealing |
IP-40 |
|
Safety |
Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition |
|
Overvoltage |
CAT III / 500V; CAT IV 300V |
|
Performance |
EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition |