Fluke T5-1000

Fluke T5-1000 Continuity Current Voltage Tester

Fluke TL175

Fluke TL175 TwistGuard Test Leads

Fluke 353 True RMS 2000 A Clamp Meter

£715.20 £596.00
Availability: In stock
SKU
2840252

Article Number: 2840252

Key features

  • Reliably handle a wide range of high-current applications with 2000 A AC + DC true-rms, 1400 A ac, and 2000 A DC
  • The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings

Fluke 353 comes complete with a calibration certificate traceable to National Standards when purchased from us at no extra charge. 

Contact us for further information regarding Fluke 353

Fluke 353 True RMS 2000 A Clamp Meter Features:

Versatile and rugged tool for applications with high currents

Confidently take reliable readings with the True RMS, Fluke 353 digital clamp meter; the tools of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads.

What's in the box:

  • Fluke 353 2000 A Clamp Meter
  • C43 Soft Carrying Case
  • 6 AA batteries (Installed)

Quick Reference Guide

Specifications: Fluke 353 True RMS 2000 A Clamp Meter

Electrical Specifications

Current measurement DC and AC 10 Hz to 100 Hz

Range

40 A / 400 A / 2000 A / 1400 AC RMS

   

Resolution

10 mA / 100 mA / 1 A

   

Accuracy

A: 1.5% rdg + 15 digits
A: 1.5% rdg + 5 digits

   

Trigger level for Inrush

0.50 A / 5.0 A / 5 A

   

Trigger level for Hz filter OFF

2.50 A / 2.5 A / 8 A

   

Trigger level for Hz filter ON

0.50 A / 2.5 A / 8 A

   

Crest Factor (50/60 Hz)

Range

40 A / 400 A / 2000 A / 1400 AC RMS

   

Crest Factor1

2 @ 33 A, 2.4 @ 27 A
2 @ 330 A, 2.4 @ 270 A
2 @ 1000 A, 2.4 @ 833 A

   

Current measurement AC 100.1 Hz to 1 kHz

Range

40 A / 400 A / 2000 A; 1400 AC RMS

   

Resolution

10 mA / 100 mA / 1 A

   

Accuracy

10 A: 3.5% rdg + 15 digits
10 A: 3.5% rdg + 5 digits

   

Trigger level for Inrush

0.50 A / 5.0 A / 5 A

   

Trigger level for Hz filter OFF

2.50 A / 2.5 A / 8 A

   

Trigger level for Hz filter ON

0.50 A / 2.5 A / 8 A

   

Frequency measurement

Measurement range

5.0 Hz to 1 kHz

   

Resolution

0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)

   

Accuracy – 5.0 Hz to 100 Hz

0.2% + 2 counts

   

Accuracy – 100.1 Hz to 1 kHz

0.5% + 5 counts

   

Trigger level

Refer to current and voltage tables

   

1. Add 2% to error spec for CF > 2

General Specifications

Batteries

Six 1.5 V AA NEDA 15 A or IEC LR6

 

Battery life (with typical usage, backlight off)

100 hours

 

Test leads

Rated to 1000 V

 

Weight

.814 kg (1.8 lb)

 

Jaw size

58 mm (2.28 in)

 

Dimensions (L x W x D)

300 x 98 x 52 mm (12 x 3.75 x 2 in)

 

Safety rating

IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III

 

Environmental Specifications

 

Operating temperature

32°F to +122°F (0°C to +50°C)

 

Storage temperature

-4°F to 140°F (-20°C to +60°C)

 

Operating humidity

0 to 95% (non-condensing)

 

Operating altitude

2000 m

 

Storage altitude

10,000 m

 

IP rating

42 (indoor use only)

 

Drop test requirements

1 m

 

EMI, RFI, EMC

FCC part 15, IEC/EN 61326-1:1997 class B
IEC/EN 61326:1997 3V/m, performance criteria B, EN61325

 

Temperature coefficients

Current

0.1% of reading per °C outside 22°C to 24°C

   

Voltage

0.1% of reading per °C outside 22°C to 24°C

   

 

Write Your Own Review
You're reviewing:Fluke 353 True RMS 2000 A Clamp Meter
Your Rating

Our Best Selling Products