Free of charge traceable calibration and certification with purchase of new Fluke 902 FC HVAC clamp meter.
Contact us if you require any further assistance with any Fluke product.
The Fluke 902 FC Clamp Meter, with Fluke Connect wireless connectivity, can help HVAC technicians improve productivity in the field. The rugged dual-rated CAT III 600 V, CAT IV 300 V meter equips you to perform many essential HVAC system measurements: microamps for testing pilot light sensors; resistance up to 60 kΩ; AC current and AC/DC voltage; capacitance; and contact temperature, all with just one tool. Plus, its small form factor makes it easy to hang on to and navigate in tight work spaces.
Part of the Fluke Connect wireless family
As part of the Fluke Connect family, the 902 FC can transmit measurements to a smartphone or tablet for later, detailed analysis. No need to write down the results. Trend and monitor measurements live on your phone screen, and upload those measurements to the cloud. Combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email, and collaborate in real time with other colleagues with ShareLive™ video calls or email.
The 902 FC can also decrease the frequency of wearing personal protective equipment (PPE) when working on high voltage/current panels. Simply turn off the panel. Verify that it is de-energized using standard safety procedures. Place the clamp and synch it to a smartphone. Close the panel, reenergize it, and take measurements from a safe distance.
Fluke Connect software can be downloaded from the following links:
Function |
||
A ac (via Jaw) |
||
Resolution |
0.1 A |
|
Accuracy |
2.0% ±5 digit (45-65 Hz) |
|
2.5% ±5 digit (65-400 Hz) |
||
Range |
600.0 A |
|
Crest Factor (50Hz or 60Hz) |
2.5 MIN@220 A |
|
V ac |
||
Resolution |
0.1 V |
|
Accuracy |
1.5% ±5 digits |
|
Range |
600.0 V |
|
V dc |
||
Resolution |
0.1 V |
|
Accuracy |
1.5% ±5 digits |
|
Range |
600.0 V |
|
Ohms |
||
Resolution |
0.1/1/10 |
|
Accuracy |
1% ±5 digits |
|
Range |
600/6000/60.00 kΩ |
|
Capacitance |
||
Resolution |
0.1/1 µF |
|
Accuracy |
1% ±4 digits |
|
Range |
100.0/1000 µF |
|
µA |
||
Resolution |
0.1 µA |
|
Accuracy |
1% ±5 digits |
|
Range |
200 µA |
|
Contact temperature |
||
Resolution |
0.1 C/F |
|
Accuracy |
1% ±8 digits |
|
Range |
-40 to 400 °C (-40 °F to 752 °F) |
|
Continuity beeper |
||
Beeper volume |
75 dBA nom. 15 cm. from case front |
|
On threshold |
<=30 Ω |
|
Mechanical and General Specifications |
||
Maximum voltage between any terminal and earth ground |
1000 V |
|
Battery type |
2 AA alkaline batteries, NEDA 15A, IEC LR6 |
|
Temperature |
Operating: -10 °C to +50 °C (14 °F to +122 °F) |
|
Operating humidity |
Non condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F)) |
|
Altitude |
Operating: 3,000 m (9,842 ft) |
|
Dimensions |
230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in) |
|
Weight (meter only) |
419 g (15 oz) |
|
Safety |
IEC 61010-1, Pollution Degree 2 |
|
IP Rating |
IEC 60529: IP30, non-operating |
|
Radio Frequency Certification |
FCC ID:T68-FBLE IC:6627A-FBLE |
|
Electromagnetic Compatibility (EMC) |
International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
|
Temperature coefficients |
Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C |
Free of charge traceable calibration and certification with purchase of new Fluke 902 FC HVAC clamp meter.
Contact us if you require any further assistance with any Fluke product.