Megger MFT1721 Multifunction Tester

Megger MFT1721 Multifunction Tester

Megger DCM300E Earth Leakage Clamp Meter

Megger DCM300E Earth Leakage Clamp Meter

Megger MFT-X1 Multifunction Tester

£2,226.00 £1,855.00
Availability: In stock
SKU
1012-223

The Megger MFT-X1 Multifunction Tester with True Loop™, industry leading loop impedance test with patented Confidence Meter™ technology, full CertSuite™ compatibility, to make certificate generation a breeze. High resolution loop testing, stabilised insulation voltage output, full colour screen and new operator interface are now standard. The user upgradeable operating software ensures the MFT-X1 has the ability to adapt to regulation changes and make it the perfect instrument for fast, reliable, accurate and adaptable testing.

  • Electrical testing of single and 3-phase installations.
  • Brand new features including full colour screen,
  • RCD configurator
  • EV charge point testing
  • Fully compatible with CertSuite™for easy certificate generation and reporting.
  • TrueLoop™ measurement using patented confidence meter.
  • Never be without power with the quick-remove battery pack and rechargeable battery option.

Intended for use on all low voltage electrical installations including EV charge points and domestic photo-voltaic systems, the range of test capabilities allow for general commissioning of installations and periodic maintenance as well as detailed fault diagnostics.

Features:

  • True Loop™ test with patented Confidence Meter™
  • CertSuite™ compatible Bluetooth® result transfer
  • Next generation 2-wire and 3-wire non-trip loop testing
  • User upgradeable operating system
  • High resolution 0.001Ω loop test
  • Automatic volt-drop measurement
  • Stabilised insulation test voltage
  • Configurable RCD and EV auto-sequence tests
  • Fast switch rechargeable plug-in battery pack
  • Full colour TFT bonded display
  • Re-designed lead set and carry case solution
  • IP54 operational housing

True Loop™ impedance testing is now a standard feature on the MFT-X1. The latest 3-wire non-trip loop testing technology, incorporated with the patented Confidence Meter™, offers an unmatched, reliable, accurate, stable and repeatable loop test solution to the user, allowing testing in the most hostile high noise conditions or close to the source of supply. The technology also removes the risk of RCD uplift whilst reducing typical test times – even on circuits protected by 6 mA or 10 mA protective devices.

All loop impedance ranges are now supported by the Megger patented Confidence meter technology, reducing typical test times for non-trip loop testing to around 7 seconds on quiet circuits, and providing optimised test times for loop impedance testing in difficult noisy supplies. The Confidence meter shows the progress of the loop measurement and indicates the presence of noise on the circuit, removing erroneous values to give a stable and consistent result.

Test results can be tagged with circuit data and transferred to CertSuite, the latest cloud base electrical certification software package from Megger.  When paired to a mobile device using the low energy

Bluetooth mode, results can be sent directly from the MFT-X1 to an Android or IOS device running Megger CertSuite software. These results are also synchronised with the cloud-based application.  With a wide range of certification options, CertSuite is available as a monthly or yearly subscription package for electrical certification of installations taking results directly from the MFT whilst testing. CertSuite is suitable for multiple concurrent users and is optimised for use with the MFT-X1.  Results can be stored and reviewed remotely by users whilst on site from different locations, accessed by head office or other users with the relevant permission, with professional looking certification and reports.

The MFT-X1 has extended the low end of the loop impedance range from 0.01 ohms to 0.001 ohms resolution and 50 kA current calculation. The True Loop impedance measurement using the patented confidence meter makes these low impedance measurements a realistic option, with two wire test connections and high current testing.

RCD testing can now be optimised with the RCD test configurator. Select a whole suite of tests or only those elements of the RCD you require. You can even add ramp testing to the sequence, optimising and simplifying testing.

Suitable for both EV charger installation testing with either RCD Type B or RDC protected charge points. The MFT-X1 in conjunction with the Megger EVCA adaptor can test all known EV chargers for installation or maintenance.

For the first time in any multifunction tester, the MFT-X1 incorporates a stabilised insulation test voltage, ensuring output voltage is accurate to within +/-3% +2 digits. This compares to the industry standard of +20% and so provides a more accurate test voltage without the risk of over-voltage damage to circuits or sensitive components.

The operating system of the MFT-X1 range is upgradable by the user, simply by downloading the latest operating system file (.BIN) from the Megger web site to a suitable microSD card. Insert the updated microSD card and pressing TEST initiates an automatic update process without the need for further user intervention.

The user interface utilises the flexibility of the high contrast 480 x 272 colour, TFT bonded display, with a monochrome black on white mode designed specifically for use in difficult lighting conditions. Enhancing the colour coded test selection rotary dial, range selection is now replicated on the instrument screen, ensuring easy use in poor lighting environments. Hot keys for second level functions are clearly shown across the top of each screen and the second control dial provides users with a further quick selection option of any highlighted feature, even if wearing protective gloves. Relevant information is clearly shown on the display, both before and after each test, in full colour, and includes the Confidence Meter™ progress bar, RCD ramp test progress as well as the insulation and continuity measurement bar graph. The new Voltage Widget, displays the L-N, L-E and N-E voltages.

The Megger MFT-X1 can be powered by either the Megger Li-ION battery pack or using standard NiMH or Alkaline batteries. The unique 4Ahr rechargeable Li-ION battery can be swapped with the AA carrier module, providing the fastest and most flexible battery change solution in the industry.

APPLICATIONS

The primary application is the testing of low voltage electrical installations in domestic, commercial, and industrial installations for single and three phase systems. The wide range of test capabilities extend the use of the MFT-X1 to include:

  • EV charge point testing
  • Domestic PV testing
  • Motor/Generator testing
  • Machine testing
  • Portable appliance safety testing
  • Panel building and switchgear manufacturing
  • Cable testing

Graphical assistance

The instrument has context help to provide graphical circuit connection guidance for each of the measurements.

What’s Included: 

  • MFT-X1 multifunction tester
  • Switched test probe SP5
  • Red, Blue, & Green test leads with probes, clips and grabbers
  • LI-ION battery 4400mAh
  • LI-ION battery charger
  • SIA10 Mains socket interface adaptor UK (boxed)
  • Neck Strap
  • Multipurpose hard base carry case
  • Quick start guide
Specifications:

Voltage measurement

Function

Range

Accuracy

 

Voltage DC

0V - ± 1000 V

± 1 % ± 3 digits

 

Voltage AC / TRMS

0V -600 V (15-500Hz)

± 2 % ± 1 digits

 

Frequency

15 Hz -99 Hz

± 0.5 % ± 2 digits

 

 

100 Hz - 500 Hz

± 2 % ± 2 digits

 

Millivolt measurement

Function

Range

Accuracy

 

mV AC/TRMS

0 mV - 1999 mV (50-60Hz)

± 1% ± 3 digits

 

mV DC

0 mV - ±1999 mV

± 1% ± 3 digits

 

Live Earth Detection

Indicates if PE terminal is live when selecting Loop or RCD ranges

The relevant Loop or RCD test is inhibited.

Current

Function

Range

Accuracy

 

Current AC/TRMS

0.001 A - 0.100 A

± 2 % ± 3 digits

 

 

0.100 A - 2.000 A

± 2 % ± 3 digits

 

 

2.00 A - 20.00 A

± 2 % ± 3 digits

 

 

20.0 A - 300 A

± 2 % ± 3 digits

 

Frequency Bandwidth

15 Hz - 500 Hz

 

Influence of Frequency

30 Hz - 500 Hz ≤0.25 %

 

Resistance and Continuity

Function

Range

Test Current

Accuracy

200 mA

0.01 Ω - 99.9 Ω

(0 Ω - 2 Ω) 205 mA ± 5 mA

± 3 % ± 2 digits

10 mA

0.01 Ω - 99.9 Ω

10 mA

± 3 % ± 2 digits

 

100 Ω - 999 Ω

 

± 3 % ± 2 digits

Open Circuit Voltage

4 V - 5 V

 

 

Insulation test

Function

Range

Accuracy

 

1000 V

0.001 - 999 MΩ

± 3 % ± 2 digits

 

500 V

0.001 - 500 MΩ

± 3 % ± 2 digits

 

 

> 500 MΩ

± 10 %

 

250 V

0.001 - 250 MΩ

± 3 % ± 2 digits

 

 

> 250 MΩ

± 10 %

 

100 V

0.001 - 100 MΩ

± 3 % ± 2 digits

 

 

> 100 MΩ

± 10 %

 

50 V

0.001 - 50 MΩ

± 3 % ± 2 digits

 

 

> 50 MΩ

± 10 %

 

Var

Leakage current > 1mA

± 3 % ± 2 digits

 

50 V - 999 V

Leakage current < 1mA

± 10 %

 

Leakage current

0.1 uA - 1.99 mA

± 10 %

 

Output voltage

-0% +2% +2 V at rated load or less

 

Voltage Display

 

± 1 % ± 3 V

 

Short circuit current

 

1.5 mA Nominal

 

Test current on load

1 mA at min pass values of insulation

 

Maximum capacitance

2 uF for a stable reading, 5 uF absolute limit

 

Loop 2 Wire - No RCD (L-PE, L-N, or L-L)

 

Function

Range

Accuracy

 

2-wire HR

0.001 Ω - 9.999 Ω

± 2 % ± 0.030 Ω

 

2-wire

0.01 Ω - 9.99 Ω

± 2 % ± 5 digits

 

10.0 Ω - 99.9 Ω

± 10 % ± 5 digits

 

100 Ω - 1999 Ω

± 10 % ± 5 digits

 

Supply voltage

48 V - 550 V

 

Supply frequency

45 Hz - 65 Hz

 

Loop 2 Wire - L-PE with RCD

Function

Range

Accuracy

 

 

0.01 Ω - 1999 Ω

± 10 % ± 5 digits

 

Supply voltage

48 V - 280 V

 

Supply frequency

45 Hz - 65 Hz

 

Loop 3 Wire - L-PE with RCD

Designation

Test Current

Application

RCD

15 mA

For circuits protected by a RCD rated <= 30 mA

RCD EV

3 mA

For EV charger circuits protected by a RDC and a type A RCD rated <= 30 mA

 

 

Function

Range

Accuracy

 

 

0.01 Ω - 9.99 Ω

± 2 % ± 5 digits

 

10.0 Ω - 199.9 Ω

± 10 % ± 5 digits

 

Supply voltage

48 V - 280 V

 

Supply frequency

45 Hz - 65 Hz

 

RCD Tests

Types A and C

RCD Types

AC, A, AC(S), A(S)

 

RCD Rated Current (IΔ n)

10 mA, 30 mA, 100 mA,

 

300 mA, 500 mA, 650 mA,

 

1000 mA, VAR

 

½ I no-trip Test current

-10 % - + 0% 0.5 IΔ n

 

1 I, 2 I, 5 I trip test - AC current

-0 % - + 10% M • IΔ n

 

2 I, 2 I, 5 I trip test - Pulsed DC current

-0 % - + 10% 1.4 • M • IΔ n

 

Trip time

± 1% ± 1 ms

 

Ramp trip test current

± 5 %

 

Fault voltage (0 V - supply)

± 5 % + 15 % ± 0.5 V

 

Supply voltage

48 V- 280 V

 

Supply frequency

45 Hz - 65 Hz

 

Types B

RCD Types

B, B(S)

 

RCD Rated Current (IΔ n)

10 mA, 30 mA, 100 mA,

 

300 mA

 

½ I no-trip Test current

-10 % - + 0% (0.5 IΔ n)

 

1 I, 2 I, 5 I trip test current

-0 % - + 10% (2 IΔ n)

 

Trip time

± 1% ± 1 ms

 

Ramp trip test current

± 5 %

 

Fault voltage (0 V - supply)

± 5 % + 15 % ± 0.5 V

 

Supply voltage

48 V- 280 V

 

Supply frequency

45 Hz - 65 Hz

 

RDC (Type EV) with a 30 mA Type A RCD

Test current

2.0 mA increasing to 6.3 mA over 2s, before being held at that current for 10s

 
 
 

Trip time

± 1% ± 1 ms

 

Ramp trip test current

± 5 %

 

Fault voltage (0 V - supply)

± 5 % + 15 % ± 0.5 V

 

Supply voltage

48 V- 280 V

 

Supply frequency

45 Hz - 65 Hz

 

Earth

Function

Range

Accuracy

 

2-wire test

0.01 Ω - 1999 Ω

± 2 % ± 5 digits

 

Test frequency

128 Hz

 

Test current

25 V 4.5 mA / 50 V 450 uA

 

 

Maximum auxiliary electrode resistance

5 kΩ for 25 V or 100 kΩ for 50 V

 

 
 

Power supply

Li-ION Rechargeable

9.2 V DC 4400 mAh (non-serviceable) + charge status

AA NiMH

9.2 V DC (using a 8xAA carrier and mounting adaptor optional)

AA Alkaline

12 V DC (using a 8xAA carrier and mounting adaptor optional)

Battery charger (Li-ION)

Input 100 V / 230 V AC 50/60 Hz 1.3 A

Output 3 A 8.4 V DC

Battery Life

Li-ION: 4400 mAh = >16 hrs *

* Times based on typical daily test profile

Battery charging time

Li-ION: 2.5 to 3 hrs (ambient temperature dependent)

Environmental

Conditions

Range

Operating Temperature

-10 °C to +55 °C

Storage Temperature

-25 °C to +70 °C

Operating Humidity

90% RH at +40 °C max

Ingress Protection

IEC 60529: IP 54

Vibration

MIL-PRF-28800F:class 2

Mechanical

Length

274 mm (10.79")

Width

96 mm (3.78")

Depth

143 mm (5.63")

Weight-instrument only

1.57 kg (3.46 lb)

Shipping weight

5.6 kg (12.35 lb)

Megger MFT-X1 Multifunction Tester comes complete with a calibration Certificate Traceable to National Standards/UKAS Test Equipment, when purchased from us, at no extra charge. 

Contact us for further information regarding Megger MFT-X1 Multifunction Tester

 

Write Your Own Review