The Fluke 1550C Insulation Tester for tests up to 5kV & the Fluke 1555 Insulation Tester for tests up to 10kV insulation.
The two models Fluke 1550C / Fluke 1555 come in kit form.
Please select option below for model required
Comes complete with a calibration Certificate Traceable to National Standards when purchased new.
The Fluke 1555 / Fluke 1550C Insulation Testers offers digital insulation testing up to 10kV, making them ideal for testing a wide range of high voltage equipment including switch gear, motors, generators and cables.
Fluke 1555 / Fluke 1550C Insulation Testers can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class and CAT IV 600 V safety rating. With measurement storage and PC interface, the Fluke 1555 / Fluke 1550C Insulation Testers are perfect tools for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.
|
Fluke 1555 / Fluke 1550C Insulation Tester Features |
||
|
||
|
Insulation resistance measurement |
||
|
250 V |
< 200 kΩ 200 kΩ to 5 GΩ 5 GΩ to 50 GΩ > 50 GΩ |
unspecified 5 % 20 % unspecified |
|
500 V |
200 kΩ 200 kΩ to 10 GΩ 10 GΩ to 100 GΩ > 100 GΩ |
unspecified 5 % 20 % unspecified |
|
1000 V |
< 200 kΩ 200 kΩ to 20 GΩ 20 GΩ to 200 GΩ > 200 GΩ |
unspecified 5 % 20 % unspecified |
|
2500 V |
< 200 kΩ 200 kΩ to 50 GΩ 50 GΩ to 500 GΩ > 500 GΩ |
unspecified 5 % 20 % unspecified |
|
5000 V |
< 200 kΩ 200 kΩ to 100 GΩ 100 GΩ to 1 TΩ > 1 TΩ |
unspecified 5 % 20 % unspecified |
|
10000 V (1555 only) |
< 200 kΩ 200 kΩ to 200 GΩ 10 GΩ to 2 TΩ > 2 TΩ |
unspecified 5 % 20 % unspecified |
|
Bar graph range |
0 to 1 TΩ |
|
|
Insulation test voltage accuracy |
-0 %, +10 % at 1 mA load current |
|
|
Induced ac mains current rejection |
2 mA maximum |
|
|
Charging rate for capacitive load |
5 seconds per µF |
|
|
Discharge rate for capacitive load |
1.5 s/µF |
|
|
Leakage current measurement |
Range: 1 nA to 2 mA |
|
|
Capacitance measurement |
Range: 0.01 µF to 15.00 µF |
|
|
Timer |
Range: 0 to 99 minutes |
|
|
Live circuit warning |
Warning Range: 30 V to 660 V ac/dc, 50/60 Hz |
|
|
General specifications |
||
|
Display |
75 mm x 105 mm |
|
|
Power |
12 V lead-acid rechargeable battery, Yuasa NP2.8-12 |
|
|
Charger Input (AC) |
Charger Input (AC) 85 V to 250 V ac 50/60 HZ 20 VA |
|
|
This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only. |
||
|
Dimensions |
170 mm x 242 mm x 330 mm (6.7 in x 9.5 in x 13 in) |
|
|
Weight |
3.6 kg (7.94 lb) |
|
|
Temperature (operating) |
-20 °C to 50 °C (-4 °F to 122 °F) |
|
|
Temperature (storage) |
-20 °C to 65 °C (-4 °F to 149 °F) |
|
|
Humidity |
80 % to 31 °C decreasing linearly to 50 % at 50 °C |
|
|
Altitude |
2000 m |
|
|
Enclosure sealing |
IP40 |
|
|
Input overload protection |
1000 V ac |
|
|
Electromagnetic compatibility |
EN 61326 |
|
|
Safety compliance |
CAT III 1000 V, CAT IV 600 V |
|
|
Pollution degree |
2 |
|
Included accessories;
Fluke 1555 / Fluke 1550C Insulation Tester comes complete with a calibration Certificate Traceable to National Standards when purchased new.
Contact us for further information regarding the Fluke 1555 1550C Insulation Tester