Fluke 1503 Insulation Tester

Fluke 1503 Insulation Tester

Fluke 1577 Insulation Multimeter Tester

Fluke 1577 Insulation Multimeter Tester

Fluke 1555 1550C Insulation Tester

As low as £4,798.80 £3,999.00
Availability: In stock
Only %1 left
SKU
Fluke 1555 1550C Insulation Tester

Fluke 1555 1550C Insulation Tester up to 10kV

The Fluke 1555 & 1550C is also available in kit form.

Included accessories;

  • Test Cables with Alligator Clips (red, black, green)
  • Infra-red adaptor with interface cable
  • Fluke view Forms Basic CD-ROM
  • AC Power lead
  • Soft Carrying Case (Base model only)
  • English Manual on CD-ROM
  • Users Manual
  • Quick Reference Card
  • Software License Agreement
  • Registration Card
  • FlukeView Forms Installation Guide
  • USB-IR Cable Installation Guide
  • IP67 Hard Case (kit only)
  • Certificate of Calibration (kit only)
  • Ruggedised Alligator Clips (kit and 1555 only)

Comes complete with a calibration Certificate Traceable to National Standards when purchased new.

The Fluke 1555 1550C Insulation Tester offers digital insulation testing up to 10kV, making them ideal for testing a wide range of high voltage equipment including switch gear, motors, generators and cables.

Fluke 1555 1550C Insulation Tester can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class and CAT IV 600 V safety rating. With measurement storage and PC interface, the Fluke 1555 1550C Insulation Testers are perfect tools for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.

 

Fluke 1555 1550C Insulation Tester Features

  • Test voltages up to 10 kV provides solutions for all applications
  • CAT III 1000 V, CAT IV 600 V safety rating
  • Voltage breakdown detection alerts the user that voltage is present and gives the voltage reading up to 600 V ac or dc for increased user safety
  • Selectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above 1000 V
  • Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
  • Long battery life gives the user over 750 tests between charges
  • Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
  • Guard system eliminates the effect of surface leakage current on high-resistance measurements
  • Large digital/analogue LCD for easy viewing
  • Capacitance and leakage current measurement
  • Ramp function for breakdown testing
  • Resistance measurements up to 2TΩ
  • Timer settings up to 99 minutes for timed tests

Insulation resistance measurement

250 V

< 200 kΩ 200 kΩ to 5 GΩ 5 GΩ to 50 GΩ > 50 GΩ

unspecified 5 % 20 % unspecified

500 V

200 kΩ 200 kΩ to 10 GΩ 10 GΩ to 100 GΩ > 100 GΩ

unspecified 5 % 20 % unspecified

1000 V

< 200 kΩ 200 kΩ to 20 GΩ 20 GΩ to 200 GΩ > 200 GΩ

unspecified 5 % 20 % unspecified

2500 V

< 200 kΩ 200 kΩ to 50 GΩ 50 GΩ to 500 GΩ > 500 GΩ

unspecified 5 % 20 % unspecified

5000 V

< 200 kΩ 200 kΩ to 100 GΩ 100 GΩ to 1 TΩ > 1 TΩ

unspecified 5 % 20 % unspecified

10000 V (1555 only)

< 200 kΩ 200 kΩ to 200 GΩ 10 GΩ to 2 TΩ > 2 TΩ

unspecified 5 % 20 % unspecified

Bar graph range

0 to 1 TΩ

Insulation test voltage accuracy

-0 %, +10 % at 1 mA load current

Induced ac mains current rejection

2 mA maximum

Charging rate for capacitive load

5 seconds per µF

Discharge rate for capacitive load

1.5 s/µF

Leakage current measurement

Range: 1 nA to 2 mA

Capacitance measurement

Range: 0.01 µF to 15.00 µF

Timer

Range: 0 to 99 minutes

Live circuit warning

Warning Range: 30 V to 660 V ac/dc, 50/60 Hz

General specifications

Display

75 mm x 105 mm

Power

12 V lead-acid rechargeable battery, Yuasa NP2.8-12

Charger Input (AC)

Charger Input (AC) 85 V to 250 V ac 50/60 HZ 20 VA

This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only.

Dimensions

170 mm x 242 mm x 330 mm (6.7 in x 9.5 in x 13 in)

Weight

3.6 kg (7.94 lb)

Temperature (operating)

-20 °C to 50 °C (-4 °F to 122 °F)

Temperature (storage)

-20 °C to 65 °C (-4 °F to 149 °F)

Humidity

80 % to 31 °C decreasing linearly to 50 % at 50 °C

Altitude

2000 m

Enclosure sealing

IP40

Input overload protection

1000 V ac

Electromagnetic compatibility

EN 61326

Safety compliance

CAT III 1000 V, CAT IV 600 V

Pollution degree

2

 