Article Number: 1592901
The Fluke 175 True-RMS digital multimeter provides the baseline multimeter features you need for troubleshooting and repairing electrical, and electronic systems.
Fluke 175 comes complete with a calibration Certificate Traceable to National Standards when purchased new.
Contact us for further information regarding the Fluke 175 true RMS digital multimeter
The Fluke 175, is battery powered, true-RMS multimeter with a 6000-count, 3 3/4-digit display and a bar graph. The Fluke 175 meter meets CAT III and CAT IV IEC 61010-1 standards. The IEC 61010 safety standard defines four overvoltage categories (CAT I to IV) based on the magnitude of danger from transient impulses. CAT III meters are designed to protect against transients in fixed-equipment installations at the distribution level; CAT IV meters are designed to protect against transients from the primary supply level (overhead or underground utility service).
Precision, reliability and ease of use the Fluke 175 DMM is suitable for troubleshooting having features needed to find most electrical, electro-mechanical, and Heating and ventalation problems. A wide range of features including the ability to measure AC voltage and AC current with true RMS readings for accurate measurements on circuits.
Voltage DC |
Accuracy1 |
± (0.15% + 2) |
Max. resolution |
0.1 mV |
|
Maximum |
1000 V |
|
Voltage AC |
Accuracy1 |
± (1.0% + 3) |
Max. resolution |
0.1 mV |
|
Maximum |
1000 V |
|
Current DC |
Accuracy1 |
± (1.0% + 3) |
Max. resolution |
0.01 mA |
|
Maximum |
10 A |
|
Current AC |
Accuracy1 |
± (1.5% + 3) |
Max. resolution |
0.01 mA |
|
Maximum |
10 A |
|
Resistance |
Accuracy1 |
± (0.9% + 1) |
Max. resolution |
0.1 Ω |
|
Maximum |
50 MΩ |
|
Capacitance |
Accuracy1 |
± (1.2% + 2) |
Max. resolution |
1 nF |
|
Maximum |
10,000 µF |
|
Frequency |
Accuracy1 |
± (0.1% + 1) |
Max. resolution |
0.01 Hz |
|
Maximum |
100 kHz |
|
1. Accuracies are best accuracies for each function |